connection |
|
ventilative sleeve pipe |
|
continues the sleeve pipe |
|
exchanger |
|
optical cable connecting tube
|
|
Wire the sub series |
|
continues the sleeve pipe |
|
optical cable connection box |
|
|
| Home → Product List → Cable product:phone
line |
| Main technical
indexes |
| No. |
Item |
Unit |
Technical requirements |
| 1 |
Surface
quality |
/ |
Smooth surface,
well-distributed color and luster, without impurity and
bleb |
| 2 |
Outer diameter |
mm |
3.1×3.7 |
| 3 |
Jacket thickness |
mm |
0.99≈1.0 |
| 4 |
Jacket minimum thickness |
mm |
0.76 |
| 5 |
Insulation thickness |
mm |
0.28 |
| 6 |
Conductor electric calcar at
20℃ |
Ω/Km |
≤92.3 |
| 7 |
Insulation resistance |
Ω·Km |
≥60 |
| 8 |
Voltage test |
K |
0.5KV/3min non puncture |
| 9 |
Circuit test |
/ |
Complete
circuit | |

Polyolefine insulated, Polyvinyl Chloride(PVC) jacket
twin copper core jacket line specifiction:HPV2×1/0.5
|
| Main technical
indexes |
| No. |
Item |
Unit |
Technical requirements |
| 1 |
Surface quality |
/ |
Smooth surface, well-distributed color and
luster, without impurity and bleb |
| 2 |
Jacket thickness |
mm |
0.72≈.07 |
| 3 |
Outer diameter |
mm |
4.07≈4.1 |
| 4 |
Insulation thickness |
mm |
≥0.3 |
| 6 |
Conductor electric calcar at 20℃ |
Ω/Km |
≤92.3 |
| 7 |
Insulation resistance |
Ω·Km |
≥60 |
| 8 |
Voltage test |
K |
0.5KV/3min non puncture |
| 9 |
Circuit test |
/ |
Complete circuit | |

Polyolefine
insulated, Polyvinyl Chloride(PVC) jacket Four core indoor line
Specification:HBYV2×2/0.5 |
| Main technical
indexes |
| No. |
Item |
Unit |
Technical requirements |
| 1 |
Surface quality |
/ |
Smooth surface, well-distributed color and
luster, without impurity and bleb |
| 2 |
Jacket thickness |
mm |
≥6.0 |
| 3 |
Insulation thickness |
mm |
≥4.0 |
| 4 |
Conductor electric calcar at 20℃ |
Ω/Km |
≤69.2 |
| 5 |
Lopsided resistance |
% |
≤4.5 |
| 6 |
Reversion test |
/ |
200mm long, reversing 360°≥27 times |
| 7 |
Rupture load test |
N |
≥400 |
| 8 |
Insulation resistance |
MΩ |
≥10 |
| 9 |
Voltage test |
KV |
-500V,lasting 3min,non
puncture | |

Polyvinyl Chloride (PVC) insulted, indoor soft line
Specification:HBGVV2×1.6/0.5
|
| Main technical
indexes |
| No. |
Item |
Unit |
Technical requirements |
| 1 |
The diameter of steel core wrapped with
copper |
mm |
|
| 2 |
Copper-plating layer thickness |
mm |
|
| 3 |
Steel core wrapped with copper line rupture
load |
N |
≥384 |
| 4 |
Conductor electric calcar at 20℃ |
Ω/km |
≤107 |
| 5 |
Conductor DC lopsided resistance |
% |
≤4.5 |
| 6 |
Working capacitance |
hf/km |
43±2 |
| 7 |
Medi-electricity strength |
kv |
1KV/1min non puncture |
| 8 |
Insulation resistance |
MΩ/km |
≥1000 |
| 9 |
Insulation thickness |
mm |
≥0.6 |
| 10 |
Insulated layer eccentricity |
mm |
≤0.05 |
| 11 |
Insulated layer ultimate stretch rate |
% |
≥300 |
| 12 |
Jacket thickness |
mm |
0.7±0.05 |
| 13 |
Jacket tensile strength (middle value) |
MPa |
≥12.5 | |
|
| □ The guide
for placing oders |
| Name |
Model |
Specification |
| Steel core phone line |
HBGVV |
2×1/1.2 |
| 4 core indoor line |
H B Y V |
2×2/0.5 |
| Indoor soft line |
HRVV |
2×16/0.15 |
| Twin jacket copper core line |
H P V |
2×1/0.5 |
| Steel core wrapped with copper line
user lead |
HBGTYV |
2×1/1.0-20 | |